Fixin’ Things: Week’s Update

Figured I would try and and get back into the swing of things and update a bit more often.  Mostly boring stuff, but, hey, someone has to do it! This week I have a bit of F.O.R.D. action to mention along with plans to  repair a Nautel NV20.  Also a little fun with NexGen and Sage communications.  A little bit of everything.

F.O.R.D. = Fix Or Repair Daily.  Harris Z10.  This box just sits there and is used on occasion when I do a Nautel update.  As it sits, it fails.  No, it doesn’t need to be turned on, it just fails.  I should clarify, it shows Faults.  Currently 4 when I look at the logs, used to be 5.  Let me remind you, it gets these just sitting idle.  Apparently 2 of the 4, was 3 of 5, are PA modules showing the PS#_OT, or over temperature fault.  Again, it isn’t running.  A little research and some interaction with tech support a couple months ago, I finally ordered the parts through Mouser and did a test repair.  This repair entails the replacement of a capacitor and thermistor.  Easy enough except they are surface mount, so I finally got a chance to experience this type of repair first hand.  All I can say is it takes patience.  Needless to say, the test PA module installed and fault is cleared.  I have 2 more to do.  The other faults I will act on when I get these obvious ones out of the way.  Unfortunately it looks like one of these pending faults corresponds to a dead PA.

But, wait, did I say a Nautel repair is imminent?  Yeah, I guess I pushed the old beast a bit too hard as I prepare for an HD carrier increase.  I began to adjust the HD PA voltage to accommodate the new power increase and two PA modules said they did not like that, and Poof!  I just finished doing some research and I have all the parts to replace them.  I even have the tools!  What did I find out today?  I have version A of the modules and all the latest documents show they are up to C, and they look more modular!  The old ones require de-soldering and then replacement.  At least it doesn’t look to bad.  I also get to perform the modifications that the modules required a few years back to improve efficiency.  All in all, I call this fun.

We us IP to control most everything these days, and this includes how the RCS NexGen communicates with the Sage Endec.  Sure enough, this week I noticed that the RWT did not fire properly.  This is normally caused by the old architecture of NexGen where it just decides to not talk.  After a couple of tests I had to do the old CTRL+Alt+Shift+F4 on the A-server so it would load a fresh database.  Why it decided to start doing this is beyond me.  The other two stations do not have this issue.  I know we will be moving off this system some day, so whatever we use better be IP savvy in running all tests and alerts.

Interspersed among all this fun is Microsoft and Windows 10.  Thanks.  Apparently there is an issue with Win 10 and USB 3.0.  At least with some of our stuff, more specifically Digigram and the UAX-220v2.  Thought he device uses generic Windows drivers, the system will throw a fault and reboot spontaneously.  When trying to track it down, the Event Logs show nothing except the “previous shutdown was unexpected” error.  I finally caught a memory dump and analysed it.  A reference to a USB device was there.  As a test I removed the UAX and that machine has settled down.  I think I will need to experiment with a couple of other USB sound devices and see if it is isolated to Digigram or it is more universal issue.  Sad if it is the UAX as the beauty of it was plug and play with no special drivers.

If you get a long weekend, enjoy!  If not, take advantage of the time you have!

 